Programming
Operating Instructions 745-35-10 S/745-35-10 A - 03.0 - 04/2017 111
Set soft start parameters
The display switches to Soft start parameters.
Fig. 93: Set soft start parameters
To edit the soft start parameters:
1. Press the desired button.
2. Enter the desired value using the numeric keypad.
3. Confirm with OK.
Symbols Meaning
Soft start On/Off
Set soft start speed
100 RPM - 1500 RPM
Set number of stitches for soft start
•1 - 20
Number of stitches for loosening the needle thread clamp
•1 - 20