6.2.6
Display Menu
Operation
Table 6-3
describes
the
menu functions
and how to use
them.
T
able
6-3. Display Menu
Operation
Function Subfunction Operation
Meters
–
UPS
The Meter screens show the
UPS
meter readings for the unit. The default voltage displayed on
these
screens is phase-to-neutral. These can be changed to display the voltage phase-to-phase (A-
B, B-C, C-A). Use the
LEFT or RIGHT
arrow pushbuttons to select the
METER symbol on the main
menu
bar, to display the Meter screens.
To
scroll through the meter screens, press the
UP or DOWN
arrow
pushbutton. The current
UPS
readings are displayed in the information area of the
screen.
Output
–
UPS
The Output
screen shows output voltage (phase to neutral), output current (each phase), and frequency
being supplied by the UPS,
as
well
as
the
kVA,
kW, and power factor
measurements.
Input
–
UPS
The Input screen shows input voltage (phase to neutral), input current (each phase), and frequency
of
the incoming utility source,
as
well
as
the
kVA,
kW, and power factor
measurements.
Bypass
The Bypass screen shows the bypass input voltage (phase to neutral), input current (each phase),
and
frequency of the incoming utility source,
as
well
as
the
kVA,
kW, and power factor
measurements.
Battery
–
UPS
The Battery screen displays the battery voltage
(Vdc)
and the battery current (Idc).
Events
Use the
LEFT or RIGHT
arrow pushbuttons to select the
EVENTS
symbol on the main menu bar to
display
the Events screens.
A
listing of all system events that are currently active is displayed. The most
recent
event is listed first. As events clear, they are removed from the Events listing.
To
scroll through
the
events, press the
UP or DOWN arrow
pushbutton.
History
Use the
LEFT or RIGHT
arrow pushbuttons to select the
HISTORY
symbol on the main menu bar
to
display the History screen. The history
Log
lists up to 512 events in chronological order, with the
most
recent event listed last (once 512 is reached, the earliest event is overwritten). The end of the log
(the
most recent events) is displayed first; scroll upward to view older event listings.
To
scroll through
the
events, press the
UP or DOWN arrow
pushbutton.
Setup
– User
Function
Selection
This screen can be used to display user information and show the firmware versions installed. Use
the
LEFT or RIGHT
arrow pushbuttons to select the
SETUP symbol on the main menu bar to display
the
Setup screen. Use the
UP or DOWN
arrow pushbutton to highlight the function desired, then press
the
RETURN
pushbutton to display the function screen. See Figure 6-6 for
a
typical screen
display.
User Info
The User Info screen provides the model,
CTO
and serial numbers of the UPS, the Output
voltage,
frequency, and
kVA
rating, the input voltage rating, and the battery run time rating. Use the
LEFT
or
RIGHT
arrow pushbuttons to select
USER
on the Setup menu bar. Use the UP or DOWN
arrow
pushbutton. to select
Info, then press the
RETURN
pushbutton to display the function screen.
To
return
to the System Setup screen, press the
ESC
pushbutton.
About
The About screen provides the firmware version numbers installed on the
UPS. Use the
LEFT
or RIGHT
arrow pushbuttons to select
USER
on the Setup menu bar. Use the UP or DOWN
arrow pushbutton.
to
select About.
To
return to the System Setup screen, press the
ESC
pushbutton.
Setup
–
Config
(System Level
1 Setup)
Password
To enter
a
password
if required, use the
LEFT or RIGHT
arrow pushbutton to select the
password
character position. Use the
UP or DOWN
arrow pushbutton to change the password character. Once
the
password is entered, select
DONE
and then press the
RETURN
pushbutton.
The System Setup
Level
1
menu screen is displayed. The default System Setup Level
1 password is
0101.
Function
Selection
This screen can be used to
set
the date and time, change the display language, enter
a
unit
name,
change the meter style, perform lamp test, clear the history log, and enter
a
password to access
Level
1
functions. Use the
LEFT or RIGHT
arrow pushbuttons to select the
SETUP symbol on the main menu
bar
to display the Setup screen. Use the
LEFT or RIGHT
arrow pushbutton to
select
CONFIG on the
Setup
menu bar.
Enter
a
password
if
required.
Clock
The Clock
Setup screen allows the selection of either month/day/year or day/month/year formats
and
daylight savings time for display on the screen and for logging events in the Event and History Logs.
Use
the UP or DOWN
arrow pushbutton to select
CLOCK
to display the Clock
screen. Use the
UP
or DOWN
arrow pushbutton to highlight the desired format, then press the
RETURN
pushbutton to display the
Set
Date and Time screen.
To
return to the System Setup screen, press the
ESC
pushbutton.
Eaton 93E MK2 UPS (10-40kVA, 380/400/415V) Installation and Operation