Appendix A
M-Max Series Adjustable Frequency Drive    MN04020003E—October 2013    www.eaton.com 157
PROFIBUS DP Fieldbus Interface Card
Note: The PROFIBUS DP fieldbus interface card 
XMX-NET-PD-A or XMX-NET-PS-A are not supplied 
with the M-Max frequency inverter.
XMX-NET-PD-A and XMX-NET-PS-A enable the connection 
(slave) of frequency inverters of the M-Max series to the 
standard PROFIBUS DP fieldbus. 
Note: The optional MMX-NET-XA mounting frame is required 
for mounting and connecting the MMX frequency 
inverter.
Technical data:
●
Communication protocol: PROFIdrive (PROFIBUS profile 
for variable speed drives)
●
Data transfer: RS485, half-duplex
Note: Further information on hardware and engineering the 
XMX-NET-NET-P_ interface card is provided in the 
manual MN04012002Z.
XMX-NET-PD-A
The fieldbus connection is implemented with a nine-pole 
Sub-D plug connector.
XMX-NET-PD-A PROFIBUS DP Fieldbus Interface Card 
with Nine-Pole Sub-D Plug Connection
Note: Detailed installation instructions are provided in 
IL04012008Z.
XMX-NET-PS-A
The fieldbus connection is implemented with a pluggable 
five-pole screw terminal.
Fieldbus Connection
Note: Detailed installation instructions are provided in 
IL04012008Z.
XMX-NET-DN-A
XMX-NET-DN-A DeviceNet Fieldbus Interface Card
Note: The DeviceNet fieldbus internet card XMX-NET-DN-A 
is not supplied with the M-Max frequency inverter.
The XMX-NET-DN-A enables the connection (slave) of 
frequency inverters of the M-Max series to the standard 
DeviceNet fieldbus.
Note: The optional MMX-NET-XA mounting frame is required 
for mounting and connecting the M-Max frequency 
inverter. 
OPTE5
XMX-NET-PS-A
OPTE3
XMX-NET-PS-A