Installation
32 M-Max Series Adjustable Frequency Drive MN04020003E—October 2013 www.eaton.com
Electrical Installation
WARNING
Carry out wiring work only after the frequency inverter
has been correctly mounted and secured.
WARNING
Electric shock hazard—risk of injuries!
Carry out wiring work only if the unit is de-energized.
CAUTION
Debounced inputs may not be used in the safety circuit
diagram.
Fire hazard!
Only use cables, protective switches, and contactors that
feature the indicated permissible nominal current value.
CAUTION
Debounced inputs may not be used in the safety circuit
diagram.
Ground contact currents in frequency inverters are greater
than 3.5 mA (AC). According to product standard IEC/EN
61800-5-1, an additional equipment grounding conductor
must be connected, or the cross-section of the equipment
grounding conductor must be at least 0.39 in
2
(10 mm
2
).
WARNING
The components in the frequency inverter’s power
section remain energized up to five (5) minutes after the
supply voltage has been switched off (intermediate
circuit capacitor discharging time).
Pay attention to hazard warnings!
Note: Complete the following steps with the specified tools
and without using force.
DANGER
5 MIN

Table of Contents

Other manuals for Eaton M-Max series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton M-Max series and is the answer not in the manual?

Eaton M-Max series Specifications

General IconGeneral
BrandEaton
ModelM-Max series
CategoryDC Drives
LanguageEnglish

Related product manuals