80 M-Max Series Adjustable Frequency Drive MN04020003E—October 2013 www.eaton.com
Digital Outputs, continued
PNU ID
Access
RUN Value/Range Description
Factory Setting
(P1.3)
P5.5 316 Frequency monitoring 1 reference value 0.00
0.00–P6.4 Hz P6.4 = maximum frequency
P5.6 346 Frequency monitoring 2 0
Monitoring of the selected frequency range
(see P5.5 for explanation)
A monitoring message can be implemented via the digital
outputs (value 11 = P5.1, P5.2, P5.3)
0 Deactivated
1 0.00–P5.7 Hz frequency is below reference P5.7
2 P5.7–P6.4 Hz frequency is above reference P5.7
(P6.4 = maximum frequency)
P5.7 347 Frequency monitoring 2 reference value 0.00
0.00–P6.4 Hz P6.4 = maximum frequency
Frequency Monitoring (P5.5–P5.7)
P5.5
P5.7
P5.4 = 1–
(Hz)
f
P5.4 = 2
P5.6 = 1–
P5.6 = 2
t