Chapter 4
| System Management Commands
Line
– 150 –
Default Setting
300 seconds
Command Mode
Line Configuration
Command Usage
If a login attempt is not detected within the timeout interval, the connection is
terminated for the session.
This command applies to both the local console and Telnet connections.
The timeout for Telnet cannot be disabled.
Using the command without specifying a timeout restores the default setting.
Example
To set the timeout to two minutes, enter this command:
Console(config-line)#timeout login response 120
Console(config-line)#
disconnect This command terminates an SSH, Telnet, or console connection.
Syntax
disconnect session-id
session-id – The session identifier for an SSH, Telnet or console connection.
(Range: 0-8)
Command Mode
Privileged Exec
Command Usage
Specifying session identifier “0” will disconnect the console connection. Specifying
any other identifiers for an active session will disconnect an SSH or Telnet
connection.
Example
Console#disconnect 1
Console#
Related Commands
show ssh (239)
show users (123)

Table of Contents

Other manuals for Edge-Core AS6700-32X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core AS6700-32X and is the answer not in the manual?

Edge-Core AS6700-32X Specifications

General IconGeneral
BrandEdge-Core
ModelAS6700-32X
CategorySwitch
LanguageEnglish

Related product manuals