Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running
the motor
Optimization
NV Media Card
Operation
Onboard
PLC
Advanced
parameters
Technical
data
Diagnostics
UL listing
information
Powerdrive F300 User Guide 107
Issue Number: 2
5.5 Advanced menus
The advanced menus consist of groups or parameters appropriate to a
specific function or feature of the drive. Menus 0 to 41 can be viewed on
the KI-HOA Keypad RTC.
The option module menus (S.mm.ppp) are only displayed if option
modules are installed. Where S signifies the option module slot number
and the mm.ppp signifies the menu and parameter number of the option
module’s internal menus and parameter.
Table 5-5 Advanced menu descriptions
*Only displayed when the option modules are installed.
5.5.1 KI-HOA Keypad RTC
To enter the keypad set-up menu press and hold the escape
button on the keypad from status mode. All the keypad parameters are
saved to the keypad non-volatile memory when exiting from the keypad
set-up menu.
To exit from the keypad set-up menu press the escape or or
button. Below are the keypad set-up parameters.
Table 5-6 KI-Keypad set-up parameters
It is not possible to access the keypad parameters via any
communications channel.
5.5.2 Display messages
The following tables indicate the various possible mnemonics which can
be displayed by the drive and their meaning.
Table 5-7 Status indications
Menu Description
0
Commonly used basic set up parameters for quick / easy
programming
1 Frequency / Speed reference
2Ramps
3 Frequency slaving, speed feedback and speed control
4 Torque and current control
5 Motor control
6 Sequencer and clock
7 Analog I/O, Temperature monitoring
8 Digital I/O
9
Programmable logic, motorized pot, binary sum, timers and
scope
10 Status and trips
11 Drive set-up and identification, serial communications
12 Threshold detectors and variable selectors
14 User PID controller
15 Option module slot 1 set-up menu
16 Option module slot 2 set-up menu
17 Option module slot 3 set-up menu
18 General option module application menu 1
19 General option module application menu 2
20 General option module application menu 3
22 Menu 0 set-up
23 Not allocated
28 Reserved menu
29 Pumping functions
30 Onboard user programming application menu
Slot 1 Slot 1 option menus*
Slot 2 Slot 2 option menus*
Slot 3 Slot 3 option menus*
Parameters Range Type
Keypad.00 Language
Classic English (0)
English (1)
RW
Keypad.01 Show Units Off (0), On (1) RW
Keypad.02 Backlight Level 0 to 100 % RW
Keypad.03 Keypad Date
01.01.10 to
31.12.99
RO
Keypad.04 Keypad Time
00:00:00 to
23:59:59
RO
Keypad.05
Show Raw Text Parameter
Values
Off (0), On (1) RW
Keypad.06 Software Version
00.00.00.00 to
99.99.99.99
RO
Upper row
string
Description
Drive
output
stage
Inhibit
The drive is inhibited and cannot be run.
The Safe Torque Off signal is not applied to
Safe Torque Off terminals or Pr 06.015 is
set to 0. The other conditions that can
prevent the drive from enabling are shown
as bits in Enable Conditions (06.010)
Disabled
Ready
The drive is ready to run. The drive enable
is active, but the drive inverter is not active
because the final drive run is not active
Disabled
Stop The drive is stopped / holding zero speed Enabled
Run The drive is active and running Enabled
Supply Loss Supply loss condition has been detected Enabled
Deceleration
The motor is being decelerated to zero
speed / frequency because the final drive
run has been deactivated
Enabled
dc injection The drive is applying dc injection braking Enabled
Trip
The drive has tripped and no longer
controlling the motor. The trip code
appears in the lower display
Disabled
Under
Voltage
The drive is in the under voltage state
either in low voltage or high voltage mode
Disabled
Heat The motor pre-heat function is active Enabled
Phasing
The drive is performing a ‘phasing test on
enable’
Enabled
NOTE