234 Powerdrive F300 User Guide
Issue Number: 2
Table 12-2 Maximum permissible continuous output current @ 40 °C (104 °F) ambient with high IP insert installed
Model
Normal Duty
Maximum permissible continuous output current (A)
for the following switching frequencies
2
kHz
3
kHz
4
kHz
6
kHz
8
kHz
12
kHz
16
kHz
200 V
03200066 6.6
03200080 8.0
03200110 11.0 9.7
03200127 12.3 11.9 11.1 10.0 9.0 6.4 4.7
04200180 14.5 13.5 12.2 10.5 9.6
04200250 14.5 13.5 12.2 10.5 9.6
05200300 25.5 25.2 24.9 24.3 23.7 22.5 21.6
400 V
03400034 3.4 3.3
03400045 4.5 4.4 4.1 3.6 3.3
03400062 5.1 5.0 4.7 4.4 4.1 3.6 3.3
03400077 7.7 7.4 6.7 6.2 5.7 5.0
03400104 8.3 7.6 6.9 6.0 5.2
03400123 8.3 7.6 6.9 6.0 5.2
04400185 8.6 8.4 6.9
04400240 8.6 8.4 6.9
05400300 17.1 15.6 14.4 12.6 11.4 9.6 8.7
575 V
05500039 3.9
05500061 6.1
05500100 10.0