Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running
the motor
Optimization
NV Media Card
Operation
Onboard
PLC
Advanced
parameters
Technical
data
Diagnostics
UL listing
information
256 Powerdrive F300 User Guide
Issue Number: 2
Table 12-39 Size 5 emission compliance (400 V drives)
Table 12-40 Size 5 emission compliance (575 V drives)
Table 12-41 Size 6 emission compliance (200 V drives)
Table 12-42 Size 6 emission compliance (400 V drives)
Table 12-43 Size 6 emission compliance (575 V drives)
Table 12-44 Size 7 emission compliance (200 V drives)
Table 12-45 Size 7 emission compliance (400 V drives)
Table 12-46 Size 7 emission compliance (575 and 690 V drives)
Table 12-47 Size 8 emission compliance (200 V drives)
Motor cable
length (m)
Switching Frequency (kHz)
234681216
Using internal filter:
0 – 4 C3 C4
0 – 10 C3 C4
No advantage to using ferrite ring
Using external filter:
0 – 20 R (C1) R (C1) I (C2) I (C2) I (C2) I (C2) I (C2)
20 – 100 I (C2) I (C2) C3 C3 C3 C3 C3
Motor cable
length (m)
Switching Frequency (kHz)
234681216
Using internal filter:
-C4
Using internal filter and ferrite ring (2 turns):
0 – 4 C3 C4
0 – 2 C3 C4
Using external filter:
0 – 20 R (C1) R (C1) I (C2) I (C2) I (C2) I (C2) I (C2)
20 – 100 I (C2) I (C2) C3 C3 C3 C3 C3
Motor cable
length (m)
Switching Frequency (kHz)
234681216
Using internal filter:
0 – 2 C3 C4
Using internal filter and ferrite ring (1 turn – no advantage to 2 turns):
0 – 2 C3 C4
0 – 5 C3 C4
0 – 7 C3 C4
0 – 10 C3 C4
Using external filter:
0 – 20 R (C1) R (C1) I (C2) I (C2) I (C2) I (C2) I (C2)
20 – 100 I (C2) I (C2) C3 C3 C3 C3 C3
Motor cable
length (m)
Switching Frequency (kHz)
2 34681216
Using internal filter:
0 – 4 C3 C4
0 – 10 C3 C4
No advantage to using ferrite ring
Using external filter:
0 – 20 R (C1) R (C1) I (C2) I (C2) I (C2) I (C2) I (C2)
20 – 100 I (C2) I (C2) C3 C3 C3 C3 C3
Motor cable
length (m)
Switching Frequency (kHz)
2 3 4 6 8 12 16
Using internal filter:
-C4
Using internal filter and ferrite ring (2 turns):
0 – 4 C3 C4
0 – 2 C3 C4
Using external filter:
0 – 20 R (C1) R (C1) I (C2) I (C2) I (C2) I (C2)
I
(C2)
20 – 100 I (C2) I (C2) C3 C3 C3 C3 C3
Motor cable
length (m)
Switching Frequency (kHz)
2346812
Using internal filter:
2 – 10 C4
Using external filter:
0 – 20 R (C1)
20 – 40 R (C1)
40 – 100 R (C1) I (C2)
Motor cable
length (m)
Switching Frequency (kHz)
234681216
Using internal filter:
2 – 10 C4
No advantage to using ferrite ring
Using external filter:
0 – 20 R (C1) R (C1) I (C2) I (C2) I (C2) I (C2) I (C2)
20 – 50 I (C2)
20 – 100 I (C2) I (C2) I (C2) – – – –
Motor cable
length (m)
Switching Frequency (kHz)
234681216
Using internal filter:
2 – 10 C4
Using external filter:
0 – 20 R (C1) I (C2) I (C2) I (C2) I (C2) I (C2) I (C2)
20 – 50 R (C1) I (C2) I (C2) I (C2) I (C2) I (C2) I (C2)
20 – 100 I (C2) I (C2) – – – – –
Motor cable
length (m)
Switching Frequency (kHz)
234681216
Using internal filter:
2 – 10 C3
No advantage to using ferrite ring
Using external filter:
0 – 20 R(C1) R(C1) R(C1) R(C1) I(C2) I(C2) I(C2)
20 – 50 R(C1) R(C1) R(C1) I(C2) I(C2) I(C2) I(C2)
50 – 100 R(C1) R(C1) I(C2) I(C2) – – I(C2)