Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running
the motor
Optimization
NV Media Card
Operation
Onboard
PLC
Advanced
parameters
Technical
data
Diagnostics
UL listing
information
92 Powerdrive F300 User Guide
Issue Number: 2
4.10.3 Line to ground varistors
Figure 4-32 Removal of size 9E and 10E line to ground varistors
To electrically disconnect the line to ground varistors, remove the screw
as highlighted above (1).
Figure 4-33 Removal of line to ground varistors (size 11E)
To electrically disconnect the line to ground varistors, remove the two
screws highlighted (1) above and remove the bracket (2).
The line to ground varistors should only be removed in special
circumstances.
The line to ground varistors should only be removed in
special circumstances such as ungrounded supplies with
more than one source, for example on ships. Where the line
to ground varistors are removed, ensure that line to ground
transients are limited to values of category II. This is to
ensure that line to ground transients do not exceed 4 kV as
the drive insulation system from power to ground is designed
to category II.Contact the supplier of the drive for more
information.