00.027 Preset Reference 4 {01.024}
±VM_SPEED_FREQ_
REF Hz
0.0 Hz RW Num US
00.029
NV Media Card Data
Previously Loaded
{11.036} 0 to 999 0 RO Num NC PT
00.030 Parameter Cloning {11.042}
None (0), Read (1), Program (2),
Auto (3), Boot (4)
None (0) RW Txt NC US
00.031 Rated Voltage {11.033} 200 V (0), 400 V (1), 575 V (2), 690 V (3) RO Txt ND NC PT
00.033
Catch A
Spinning Motor
{06.009}
Disable (0),
Enable (1),
Fwd Only (2),
Rev Only (3)
Disable (0) RW Txt US
00.034 User Security Code {11.030} 0 to 2147483647 0 RW Num ND NC PT US
00.035 Serial Mode {11.024}
8 2 NP (0), 8 1 NP (1), 8 1 EP (2), 8 1 OP (3),
8 2 NP M (4), 8 1 NP M (5), 8 1 EP M (6),
8 1 OP M (7), 7 2 NP (8), 7 1 NP (9),
7 1 EP (10), 7 1 OP (11), 7 2 NP M (12),
7 1 NP M (13), 7 1 EP M (14), 7 1 OP M (15)
8 2 NP (0) RW Txt US
00.036 Serial Baud Rate {11.025}
300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4),
9600 (5), 19200 (6), 38400 (7), 57600 (8),
76800 (9), 15200 (10)
19200 (6) RW Txt US
00.037 Serial Address {11.023} 1 to 247 1 RW Num US
00.038
Current Controller Kp
Gain
{04.013} 0 to 30000 20 150 RW Num US
00.039
Current Controller Ki
Gain
{04.014} 0 to 30000 40 2000 RW Num US
00.040 Auto-tune {05.012} 0 to 2 0 to 5 0 to 6 0 RW Num NC
00.041
Maximum Switching
Frequency
{05.018}
2 kHz (0), 3 kHz (1), 4 kHz (2), 6 kHz (3),
8 kHz (4), 12 kHz (5), 16 kHz (6)
3 kHz (1) RW Txt RA US
00.042
Number Of Motor
Poles
{05.011} Automatic (0) to 480 Poles (240) Automatic (0)
6 Poles
(3)
RW Num US
00.043 Rated Power Factor {05.010} 0.000 to 1.000 0.850 RW Num RA US
00.044 Rated Voltage {05.009} ±VM_AC_VOLTAGE_SET V
200V drive: 230V 50Hz default
400V drive: 400V 60Hz default
400V drive: 460V
575V drive: 575V
690V drive: 690V
RW Num RA US
00.045 Rated Speed {05.008} 0 to 33000 rpm 0.00 to 33000.00 rpm
Eur - 1500 rpm
USA - 1800 rpm
Eur -
1450.00
rpm
USA -
1750.00
rpm
3000.00
rpm
RW Num US
00.046 Rated Current {05.007} ±VM_RATED_CURRENT A
Maximum Rated Current
(11.060) A
RW Num RA US
00.047
Rated Frequency {05.006} 0.0 to 550.0 Hz
50Hz: 50.0
60Hz: 60.0
RW Num US
Volts per 1000 rpm
{05.033}
0 to 10000
V
/ 1000 rpm
98 V /
1000
rpm
RW Num US
00.048 User Drive Mode {11.031} Open-loop (1), RFC-A (2), RFC-S (3) Open-loop (1)
RFC-A
(2)
RFC-S
(3)
RW Txt ND NC PT
00.049 User Security Status {11.044}
Menu 0 (0), All Menus (1), Read-only Menu 0 (2),
Read-only (3), Status Only (4), No Access (5)
Menu 0 (0) RW Txt ND PT
00.050 Software Version {11.029} 0 to 99999999 RO Num ND NC PT
00.051
Action On Trip
Detection
{10.037} 00000 to 11111 00000 RW Bin US
00.052
Reset Serial
Communications
{11.020} Off (0) or On (1) Off (0) RW Bit ND NC
00.053
Motor Thermal
Time Constant 1
{04.015} 1.0 to 3000.0 s 89.0 s RW Num US
00.054
RFC Low
Speed Mode
{05.064}
Injection (0)
, Non-
salient
(1)
Non-
salient
(1)
RW Txt US
00.055
Low Speed
Sensorless
Mode Current
{05.071}
0.0 to
1000.0 %
20.0 % RW Num RA US
00.056 No-load Lq {05.072}
0.000 to
500.000
mH
0.000
mH
RW Num RA US
Parameter
Range Default
Type
OL RFC-A RFC-S OL RFC-A RFC-S