Issue Number: 2
User Prog Trip Trip generated by an onboard user program
96
This trip can be initiated from within an onboard user program using a function call which defines the sub-trip number.
Recommended actions:
Check the user program
User Save User Save error / not completed
36
The User Save trip indicates that an error has been detected in the user save parameters saved in non-volatile memory.
For example, following a user save command, If the power to the drive was removed when the user parameters were being
saved.
Recommended actions:
Perform a user save in Pr mm.000 to ensure that the trip doesn’t occur the next time the drive is powered up.
Ensure that the drive has enough time to complete the save before removing the power to the drive.
User Trip Motor Rated Current Pr 05.007 or Motor Rated Speed Pr 05.008 not recognized as valid for an LSRPM motor
40
A ‘User Trip 40’ is generated if the Motor Rated Current Pr 05.007or the Motor Rated Speed Pr 05.008 is not recognized as
being a valid value for a Dyneo LSRPM motor.
Recommended actions:
Check the user program
User Trip User generated trip
41 -89
112 -159
These trips are not generated by the drive and are to be used by the user to trip the drive through an application program.
Recommended actions:
Check the Motor Rated Current Pr 05.007and the Motor Rated Speed Pr 05.008 entered into the drive against the
Dyneo LSRPM motors listed in Table 7-3 and Table 7-9 Dyneo LSRPM 5500 rpm motors on page 145.
Watchdog Control word watchdog has timed out
30
The Watchdog trip indicates that the control word has been enabled and has timed out
Recommended actions:
Trip Diagnosis