14.059 PID1 Mode Selector
Fbk1 (0), Fbk2 (1), Fbk1 + Fbk2 (2), Min Fbk (3),
Max Fbk (4), Av Fbk (5), Min Error (6), Max Error (7)
Fbk1 (0) RW Txt US
14.060 PID1 Feedback Square Root Enable 1 Off (0) or On (1) Off (0) RW Bit US
14.061 PID2 Feedback Square Root Enable Off (0) or On (1) Off (0) RW Bit US
14.062 PID1 Feedback Square Root Enable 2 Off (0) or On (1) Off (0) RW Bit US
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered