Table 12-20 Cable ratings (575 V)
Table 12-21 Cable ratings (690 V)
12.1.22 Protective ground cable ratings
Table 12-22 Protective ground cable ratings
12.1.23 Maximum motor cable lengths
Table 12-23 Maximum motor cable lengths (200 V drives)
Model
Cable size (IEC)
mm
2
Cable size (UL)
AWG
Input Output Input Output
Nominal Maximum Nominal Maximum Nominal Maximum Nominal Maximum
05500030
0.75
1.5
0.75
1.5
16
16
16
1605500040
11
14 14
05500069
1.5 1.5
14 14
06500100
2.5
25
2.5
25
14
3
14
3
06500150
4
41010
06500190
6
61010
06500230
10
10
88
06500290 66
06500350
16
66
07500440
16
25
16
25
4
3
4
3
07500550
25 25
33
08500630
35
50
35
50 1 1 1 1
08500860
50 50
Model
Cable size (IEC)
mm
2
Cable size (UL)
AWG
Input Output Input Output
Nominal Maximum Nominal Maximum Nominal Maximum Nominal Maximum
07600190
10
25
10
25
8
3
8
3
07600240 66
07600290 66
07600380
16 16
44
07600440
16 16
44
07600540
25 25
33
08600630
50
70
50
70
2
1/0
2
1/0
08600860
70 70
1/0 1/0
Input phase
conductor size
Minimum ground conductor size
≤ 10 mm
2
Either 10 mm
2
or two conductors of the
same cross-sectional area as the input
phase conductor (an additional ground
connection is provided on sizes 3, 4 and 5
for this purpose).
> 10 mm
2
and ≤ 16 mm
2
The same cross-sectional area as the input
phase conductor
> 16 mm
2
and ≤ 35 mm
2
16 mm
2
> 35 mm
2
Half of the cross-sectional area of the input
phase conductor
200 V Nominal AC supply voltage
Model
Maximum permissible motor cable length for each of
the following switching frequencies
2
kHz
3
kHz
4
kHz
6
kHz
8
kHz
12
kHz
16
kHz
03200050 65 m (210 ft)
50 m
(165 ft)
37 m
(120 ft)
03200066 100 m (330 ft)
75 m
(245 ft)
03200080 130 m (425 ft)
100 m
(330 ft)
03200106 200 m (660 ft)
150 m
(490 ft)
04200137
200 m (660 ft)
150 m
(490 ft)
100 m
(330 ft)
75 m
(245 ft)
50 m
(165 ft)
37 m
(120 ft)
04200185
05200250 200 m (660 ft)
150 m
(490 ft)
100 m
(330 ft)
75 m
(245 ft)
50 m
(165 ft)
37 m
(120 ft)
06200330
300 m
(984 ft)
200 m
(660 ft)
150 m
(490 ft)
100 m
(330 ft)
75 m
(245 ft)
50 m
(165 ft)
06200440
07200610
250 m (820 ft)
185 m
(607 ft)
125 m
(410 ft)
90 m
(295 ft)
07200750
07200830
08201160
250 m (820 ft)
185 m
(607 ft)
125 m
(410 ft)
90 m
(295 ft)
08201320

Table of Contents

Other manuals for Emerson Unidrive M702

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Unidrive M702 and is the answer not in the manual?

Emerson Unidrive M702 Specifications

General IconGeneral
BrandEmerson
ModelUnidrive M702
CategoryController
LanguageEnglish

Related product manuals