5 Operating Conditions
5.1 Absolute Maximum Ratings
Table 46 indicates the absolute maximum ratings for Mercury ZX1 SoC module. The values given are for
reference only; for details please refer to the Zynq-7000 DC and AC Switching Characteristics Datasheet [23].
Symbol Description Rating Unit
VCC_MOD Supply voltage relative to GND -0.5 to 16 V
VCC_BAT Supply voltage for the RTC and encryption key storage -0.3 to 3.6 V
VCC_IO_B13
Output drivers supply voltage relative to GND -0.5 to 3.6 V
VCC_CFG_MIO_B12
VCC_IO_B33/34 Output drivers supply voltage relative to GND -0.5 to 2.0 V
V_IO I/O input voltage relative to GND -0.5 to V
CCO
+0.5 V
Temperature
Temperature range for commercial modules (C)
*
0 to +70
C
Temperature range for industrial modules (I)
*
-40 to +85
C
Table 46: Absolute Maximum Ratings
D-0000-403-002 51 / 56 Version 05, 25.07.2019