Liquicap M FMI51 HART Electrical connection
Endress+Hauser 27
Cable entries
nickel-plated brass
⌀d = 7 to 10.5 mm (0.28 to 0.41 in)
synthetic material
⌀d = 5 to 10 mm (0.2 to 0.38 in)
stainless steel
⌀d = 7 to 12 mm (0.28 to 0.47 in)
5.1.4 Connector
For the version with a connector M12, the housing does not have to be opened for
connecting the signal line.
PIN assignment for M12 connector
2
1
34
A0011175
1 Positive potential
2 Not used
3 Negative potential
4 Ground
5.1.5 Supply voltage
All of the following voltages are terminal voltages directly at the device:
12.0 to 36.0 V
DC
in the non-hazardous area
12.0 to 30.0 V
DC
in the Ex ia hazardous area
14.4 to 30.0 V
DC
in the Ex d hazardous area
5.2 Wiring and connecting
5.2.1 Connection compartment
Depending on explosion protection, the connection compartment is available in the
following variants:
Standard protection
polyester housing F16
stainless steel housing F15
aluminum housing F17
aluminum housing F13
stainless steel housing F27
aluminum housing T13, with the separate connection compartment
Ex ia protection
polyester housing F16
stainless steel housing F15
aluminum housing F17
aluminum housing F13
stainless steel housing F27
aluminum housing T13, with the separate connection compartment