Technical data Proline Promass F 300 EtherNet/IP
230
Interface/protocol
Via digital communication:
EtherNet/IP
Via service interface
CDI-RJ45 service interface
WLAN interface
Plain text display With information on cause and remedial measures
Web server
Plain text display With information on cause and remedial measures
Light emitting diodes (LED)
Status information Status indicated by various light emitting diodes
The following information is displayed depending on the device version:
Supply voltage active
Data transmission active
Device alarm/error has occurred
EtherNet/IP network available
EtherNet/IP connection established
Diagnostic information via light emitting diodes
Low flow cut off The switch points for low flow cut off are user-selectable.
Galvanic isolation The outputs are galvanically isolated from one another and from earth (PE).
Protocol-specific data
Protocol The CIP Networks Library Volume 1: Common Industrial Protocol
The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP
Communication type 10Base-T
100Base-TX
Device profile Generic device (product type: 0x2B)
Manufacturer ID 0x11
Device type ID 0x103B
Baud rates Automatic ¹⁰⁄₁₀₀ Mbit with half-duplex and full-duplex detection
Polarity Auto-polarity for automatic correction of crossed TxD and RxD pairs
Supported CIP connections Max. 3 connections
Explicit connections Max. 6 connections
I/O connections Max. 6 connections (scanner)
Configuration options for
measuring device
DIP switches on the electronics module for IP addressing
Manufacturer-specific software (FieldCare)
Add-on Profile Level 3 for Rockwell Automation control systems
Web browser
Electronic Data Sheet (EDS) integrated in the measuring device
Configuration of the EtherNet
interface
Speed: 10 MBit, 100 MBit, auto (factory setting)
Duplex: half-duplex, full-duplex, auto (factory setting)