Proline Promass F 300 EtherNet/IP Technical data
239
High-temperature version –50 to +350 °C (–58 to +662 °F) For nominal diameters DN 25 (1"),
DN 50 (2") and DN 80 (3")
Order code for "Measuring tube
mat., wetted surface", option TT,
TU
Low-temperature version –196 to +150 °C (–320 to +302 °F)
NOTICE
Material fatigue due to excessive
temperature differential.
‣
The maximum temperature
differential of the fluid used
must not exceed 300 K.
Order code for "Measuring tube
mat., wetted surface", option LA
Dependency of ambient temperature on medium temperature
A0031121
30 Exemplary representation, values in the table below.
T
a
Ambient temperature
T
m
Medium temperature
A Maximum permitted medium temperature T
m
at T
a max
= 60 °C (140 °F); higher medium temperatures T
m
require a reduced ambient temperature T
a
B Maximum permitted ambient temperature T
a
for the maximum specified medium temperature T
m
of the
sensor
Values for devices used in the hazardous area:
Separate Ex documentation (XA) for the device → 256.
Not insulated Insulated
A B A B
Version T
a
T
m
T
a
T
m
T
a
T
m
T
a
T
m
Standard version 60 °C (140 °F) 150 °C (302 °F) – – 60 °C (140 °F) 110 °C (230 °F) 55 °C (131 °F) 150 °C
(302 °F)
Extended
temperature
version
60 °C (140 °F) 170 °C (338 °F) 55 °C (131 °F) 240 °C
(464 °F)
60 °C (140 °F) 110 °C (230 °F) 50 °C (122 °F) 240 °C
(464 °F)
High-temperature
version
60 °C (140 °F) 350 °C (662 °F) – – 60 °C (140 °F) 350 °C (662 °F) – –