EasyManua.ls Logo

Endress+Hauser Proline Prosonic Flow 93 - Page 148

Endress+Hauser Proline Prosonic Flow 93
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Technical data PROline Prosonic Flow 93 PROFIBUS-DP/-PA
148 Endress+Hauser
Degree of protection Transmitter Prosonic Flow 93:
IP 67 (NEMA 4X)
Flowrate measuring sensors Prosonic Flow P (Clamp On):
IP 68 (NEMA 6P)
Flowrate measuring sensors Prosonic Flow W (Clamp On)
IP 67 (NEMA 4X)
Flowrate measuring sensors Prosonic Flow U (clamp on):
IP 52
Flowrate measuring sensors Prosonic Flow W (Insertion version):
IP 68 (NEMA 6P)
Sound velocity measuring sensors DDU 18:
IP 68 (NEMA 6P)
Wall thickness measuring sensor DDU 19:
IP 67 (NEMA 4X)
Shock and vibration
resistance
According to IEC 68-2-6
Electromagnetic
compatibility
(EMC)
To EN 61326/A1 (IEC 1326) “Emmision to class A requirements” and
NAMUR Recommendations NE 21
Process
Medium temperature
range
Flowrate measuring sensors Prosonic Flow P (Clamp On):
–40...+80 °C / 0...+170 °C
Flowrate measuring sensors Prosonic Flow W (Clamp On):
–20...+80 °C
Flowrate measuring sensors Prosonic Flow U (clamp on):
–20...+80 °C
Flowrate measuring sensors Prosonic Flow W (Insertion):
–40...+80 °C
Sound velocity measuring sensors DDU 18:
–40...+80 °C / 0...+170 °C
Wall thickness measuring sensor DDU 19:
0...+60 °C
Medium pressure range
(nominal pressure)
Perfect measurement requires that the static fluid pressure is higher than vapour
pressure.
Maximum nominal pressure for the W sensors (Insertion): PN 16 (PSI 232)
Pressure loss There is no pressure loss.

Table of Contents