Connecting Power to the Switch
Enterasys I-Series Hardware Installation Guide 2-21
Do not connect power at this time.
Connecting to Two Power Sources
Refer to Figure 2-17 as you perform the following procedure.
To connect two power sources:
1. Ground the I-Series chassis by attaching a 14 to 20 AWG solid copper ground cable
(customer-provided) to the ground connector on the front panel of the chassis directly below
the power connectors.
2. Make sure the power supply is currently disconnected.
3. Identify the positive and negative leads.
4. Make sure the wires (14 to 20 AWG solid copper, customer-provided) are stripped to 0.25 inch
(6.3 mm) +
0.02 inch (0.5 mm). Stripping more can leave exposed wire from the power
connector.
5. Insert the positive wire from the primary source into the primary connector (marked +), as
shown in Figure 2-17. Turn the screw to secure the wire.
Figure 2-17 Connecting Power
6. Insert the negative wire from the primary source into the primary connector (marked -), as
shown in Figure 2-17. Turn the screw to secure the wire.
7. Insert the positive wire from the secondary source into the secondary connector (marked +), as
shown in Figure 2-17. Turn the screw to secure the wire.
8. Insert the negative wire from the secondary source into the secondary connector (marked -), as
shown in Figure 2-17. Turn the screw to secure the wire.
Do not connect power at this time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys I Series and is the answer not in the manual?

Enterasys I Series Specifications

General IconGeneral
BrandEnterasys
ModelI Series
CategorySwitch
LanguageEnglish

Related product manuals