Stylus Pro 4880 Field Repair Guide 1/17/08
Ink Bay Removal (Right) Printer Component, Software Item, LCD Display, Printer Button Page 62.
8. Remove 2 Screws from the back of the Ink Bay Assembly.
9. Disconnect the 4 Foil CSIC Cables and the Cartridge Release Sensor Cable.
View is from the
back of the Printer
Pump Assembly
Remove 2 Screws
Cartridge
Release Sensor
Cable
4 CSIC Cables
Re-assembly Note: Cable Order
Top to Bottom
Black, Light Cyan, Light
Magenta, Light Black