2-24 Assembly and Disassembly Rev.D
Confidential
29. Solder four carriage motor cables and three H. P. detector assembly cables to the
intermediate circuit board assembly.
30. Solder intermediate cables A, B, C to the intermediate circuit board assembly.
31. Cover intermediate cables A, B, C with the intermediate cable tube. Fold the intermediate
cables A, B, C to the right side.
Solder the carriage motor cables (four cables) to the intermediate
circuit board assembly. (See the figure below.)
Figure 2-24
WARNING:
Be careful to solder the cables to the correct connect connections. The wires may need
to be crossed. If the cables are soldered to wrong connection, the following will occur:
The wrong connection of the carriage motor cable causes a power on selt check
failure.
771
Intermediate cable tube
Three cables
for H.P. detector
assembly
Four cables
for motor
carriage
734 Intermediate cable (type A)
735 Intermediate cable (type B)
736 Intermediate cable (type C)
708 Intermediate circuit board assembly
THe leading of wire newly is indicated in the right figure.
Cable #1 (Purple) is attached to point silked with (Red).
Cable #3 (Gray)is attached to point silked with (Wht).
Cable #4 (Gray)is attached to point silked with (Org).
Cable #2 (Gray)is attached to point silked with (Ble).