Rev.D Assembly and Disassembly 2-63
TM-U675/U675P (with autocutter) Service Manual
Confidential
22. Attach the validation detector assembly to the slip guide lower frame with one screw.
Note:
The parts used and the shape of the slip guide lower frame will vary based on the specifications. Use
only the one that matches your configuration.
23. Attach the validation stopper and validation stopper spring to the slip guide lower frame.
24. Hook the cable line of the slip B.O.F. detector assembly to the slip guide lower frame.
Figure 2-63
662
Slip guide lower frame
662
673
Validation stopper spring
696
Slip B.O.F. detector assembly
673
672
672 Validation stopper
609
Screw (C.B.P-tite, 3X6)
697
Validation detector assembly