EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Disassembling the Printer Mechanism 113
Confidential
4.5.3 Hopper
Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover
Removal procedure
1. Release the dowel A of the Hopper.
2. Release the dowel B of the Hopper, and remove the Hopper together with the
Compression Spring 1.94.
Figure 4-52. Removing the Hopper
Dowel B
Dowel A
Hopper
Compression Spring 1.94
When installing the Hopper, be sure to engage the rib of the
Hopper with the guide groove of the Base Frame.
Figure 4-53. Installing the Hopper
A D J U S T M E N T
R E Q U I R E D
Whenever the Hopper is removed/replaced, the required
adjustments must be carried out.
Chapter 5 “ ADJUSTMENT” (p.150)