EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Removing the Housing 95
Confidential
4.3.3 Scanner Unit/ADF Unit
Parts/Components need to be removed in advance: None
Removal procedure
1. Remove the screw (x1) that secures the Interface Cover and release the hooks
(x2), and then remove the Interface Cover in the direction of the arrow.
Figure 4-3. Removing the Interface Cover
2. Peel off the Scanner Carriage FFC secured with the double-sided tapes (x2)
from the Left Frame.
3. Peel off the acetate tape and remove the screw (x1) that secures the grounding
wires (x2) of the Scanner Unit and ADF Unit.
4. Disconnect the Scanner Motor cable (CN11), Scanner Carriage FFC (CN17),
ADF Sensor cable (CN18) and ADF Motor connector cable (CN19) from the
connectors on the Main Board.
Figure 4-4. Removing the Scanner Unit/ADF Unit (1)
C H E C K
P O I N T
When removing the ADF Unit individually, follow the procedure
below.
1.
Step 1 and 4 of
4.3.3 Scanner Unit/ADF Unit (p95)
2. All the steps of
4.6.1 Separating the Scanner Unit and the ADF
Unit (p135)
Rib
C.B.P. 3x10, F/Zn-3C (6±1kgfcm)
Hook
Left Rear
Interface Cover
CN17
Acetate tape
Rear side of Scanner
Carriage FFC
Grounding wires
CN19
CN18
CN11
C.B.S. 3x6, F/Zn-3C (4±0.5kgfcm)
Double-sided
tape