5. Remove the screws (x1) that secure the Scanner Unit.
6. Open the Scanner Unit.
7. Remove the Scanner Unit and the ADF Unit by pulling them out in the
direction of the arrow while taking care not to hook the cables of the Scanner
Unit and ADF Unit to the Upper Housing.
Figure 4-5. Removing the Scanner Unit/ADF Unit (2)
Check the following points when routing the cables of the
Scanner Unit and the ADF Unit.
• To prevent the cables from getting caught, place the cables
and the ferrite cores (x2) inside the printer and make sure not
to let them out of the line as shown in the figure below.
Figure 4-6. Routing the cables
• Fold back the Scanner Carriage FFC at the fold shown below.
• Align the ferrite core with the line mark, then secure it to the
Left Frame with double-sided tapes (x2).
Figure 4-7. Routing the cables Scanner Carriage FFC