EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Disassembling the Scanner Unit 135
Confidential
4.6 Disassembling the Scanner Unit
4.6.1 Separating the Scanner Unit and the ADF Unit
Parts/Components need to be removed in advance
Scanner Unit/ADF Unit
Removal procedure
1. Remove the screw (x1) and remove the Scanner Cable Cover.
2. Peel off the acetate tape bundling the ADF Sensor Cable, ADF Motor Cable,
Scanner Motor Cable and the grounding wires (x2) together.
3. Release the cables (x5) from the rib (1).
4. Remove the ADF Sensor cable from the rib (2) and separate the cables (x5)
into the ADF Motor cable, ADF Sensor cable, Scanner Motor cable and the
grounding wires (x2).
Figure 4-114. Separating the Cables
5. Remove the ferrite core from the ADF Motor cable.
Figure 4-115. Removing the ADF Unit (1)
6. While lifting the ADF Unit, release the hooks (x2) of the Scanner Unit that
secure the ADF Hinges (x2) with a flathead precision screwdriver.
Figure 4-116. Removing the ADF Unit (2)