EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Removing the Housing 100
Confidential
4.3.5 Panel Unit
Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover
Removal procedure
1. Pull out the Panel Unit in the direction of the arrow (1) while pulling the Panel
Lever.
2. Push the Panel Shafts into the Panel Unit (x2) in the direction of the arrow
(2) with a flathead screwdriver etc. and remove the Panel Shafts (x2) from the
grooves (x2) of the Upper Housing.
Figure 4-16. Removing the Panel Unit (1)
3. Remove the ferrite core from the Pressing plate of the Upper Housing in the
direction of the arrow (1), and peel off the Panel FFC from the Upper
Housing.
4. Remove the grounding wire from the grooves (x8) of the Upper Housing.
5. Slide the Panel Unit in the direction of the arrow (2) while pulling the Panel
Lever, and remove the Panel Unit from the Upper Housing.
Figure 4-17. Removing the Panel Unit (2)
Panel Shaft
2
Groove
Back side
Upper Housing
1
Panel Unit
Panel Unit
Double-sided tape
Fold
Pull out the Panel FFC
from the hole of the
Upper Housing.
Ferrite core
Pressing Plate
Groove
1
Panel Lock
Panel FFC
Grounding wire
2

Table of Contents