EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Removing the Housing 99
Confidential
9. Remove the Cover Open Sensor cable and Panel FFC from the connectors
(CN8, CN20) on the Main Board and remove the Upper Housing.
Figure 4-12. Removing the Upper Housing (4)
10. Release the hook securing the Cover Open Sensor and remove the Open
Sensor from the Upper Housing in the direction of the arrow.
Figure 4-13. Removing the Cover Open Sensor
Panel FFC
Cover Open Sensor cable
CN8
CN20
Main Board
Groove
Hook
Rib
Back side
Cover Open Sensor Cable
Cover Open Sensor
Check the following points when installing the Upper Housing.
Route the Cover Open Sensor cable through the grooves (x3)
of the Upper Housing as shown in Figure. 4-13.
Align the grooves of Mall Left and those of Mall Right (Left
x4, Right x6) with the Upper Housing as shown below.
Set the part of the Mall Right shown below on the Upper
Housing.
Figure 4-14. Installing the Upper Housing (1)
When replacing the Upper Housing, make sure to attach the
Cartridge Position Label aligning it with the area (slightly
hollowed area) shown in the figure below.
Figure 4-15. Installing the Upper Housing (2)
When installing the Cover Open Sensor, insert the rib of the
Sensor into the Upper Housing and secure it with the hook as
shown in
Figure. 4-13.
Groove
Mall Left
Mall Right
Cartridge Position Label
Hollowed area