EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Disassembling the Printer Mechanism 126
Confidential
4.5.14 CR Unit
Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover/Printer Mechanism/
Card Slot Cover/Main Board Unit/Left Frame/Front Frame/Right Frame/CR
Motor/CR Scale/Hopper/Main Frame Assy/Printhead
Removal procedure
1. Remove the screw (x1) that secures the CR Scale Holder, and remove the CR
Scale Holder.
2. Move the CR Unit in the direction of the arrow to remove the CR Unit.
Figure 4-86. Removing the CR Unit (1)
Tighten the screws in the order given in Figure. 4-83.
Follow the steps below to install the Extension Spring 10.99 to
the Upper Paper Guide.
1. Attach the one end of the Extension Spring 10.99 to the
hook of the Upper Paper Guide.
2. Attach the other end of the Extension Spring 10.99 to the
hook of the Main Frame with longnose pliers.
Figure 4-85. Installing the Extension Spring 10.99