EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Disassembling the Printer Mechanism 112
Confidential
4.5.2 CR Scale
Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/ Middle Cover
Removal procedure
1. Release the right end of the CR Scale from the hook.
2. Pull out the CR Scale through the slit of the CR Encoder Sensor.
Figure 4-50. Removing the CR Scale (1)
3. Release the Extension Spring 3.289 from the hook of the Main Frame.
4. Rotate the CR Scale 90 degrees as shown in the figure and remove the scale
from the Main Frame.
Figure 4-51. Removing the CR Scale (2)
C A U T I O N
Pay attention to the following instructions:
Do not touch the CR Scale with bare hands.
Do not damage the CR Scale.
Do not stretch Extension Spring 3.289 too much.
CR Scale
Slit of CR Encoder Sensor
Hook
CR Scale
When installing the CR Scale, pay attention to the following
instructions:
Chipped part of the CR Scale must face upward.
CR scale should be passed through the slit of the CR Encoder
Sensor.
Make sure that the Extension Spring 3.289 is not be twisted,
and then attach its end to the hook of the Main Frame.
90 degrees
Chipped
CR Scale
Hook
Extension Spring 3.289