EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Disassembling the ADF Unit 139
Confidential
5. Remove the screw that secures the grounding wire to the Scanner Motor Unit,
and remove the grounding wire.
Figure 4-127. Removing the Scanner Motor Unit (2)
4.7 Disassembling the ADF Unit
4.7.1 ADF Hinge
Parts/Components need to be removed in advance: Scanner Unit/ADF Unit
Removal procedure
1. Release the dowels (x2 each) that secure the ADF Hinges, and remove the
ADF Hinges from the ADF Base.
Figure 4-128. Removing the ADF Hinges
When installing the Scanner Motor Unit, route the Scanner Motor
Cable and the grounding wire as shown in