EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Removing the Housing 97
Confidential
4.3.4 Upper Housing /Hinge/Middle Cover
Parts/Components need to be removed in advance: None
Scanner Unit/ADF Unit
Removal procedure
1. Remove the screw (x1) and remove the Hinge from the Upper Housing.
2. Release the hooks (x2) of the Middle Cover with a flathead screwdriver etc.
and remove the Middle Cover from the Upper Housing.
Figure 4-9. Removing the Upper Housing (1)
When installing the Interface Cover, insert the ribs (x5) of the
Interface Cover inside the Housing as shown in
Figure. 4-3 and
secure them with the hooks (x2).
Install the Scanner Unit and ADF Unit following the procedure
below.
1. Insert the dowel of the Upper Housing at the right inside of
the printer to the positioning hole of the Scanner Unit.
2. Insert the rib of the hinge to the space inside the ribs ( )
of the Scanner Unit.
Figure 4-8. Installing the Scanner Unit/ADF Unit