EasyManua.ls Logo

Epson WorkForce 600 - Page 146

Epson WorkForce 600
169 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
DISASSEMBLY/ASSEMBLY Disassembling the ADF Unit 147
Confidential
2. Remove the screws (x2) that secure the ADF Motor Unit.
3. Remove the torsion spring from the ADF EJ Roller, and remove the ADF
Motor Unit from the ADF Frame Unit.
Figure 4-145. Removing the ADF Motor Unit (1)
ADF EJ Roller
Torsion spring
Shaft and hole
ADF Frame Unit
ADF Motor Unit
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)
ADF Motor Unit
When installing the ADF Motor Unit, check the following points.
Attach the torsion spring from under the ADF EJ Roller as
shown below.
Figure 4-146. Handling the Torsion Spring
Insert the shaft of the ADF Motor Unit as shown in the Figure.
4-145 to the hole of the ADF Frame Unit.
Route the ADF Motor Cable and grounding wire as shown in
the figure below.
Figure 4-147. Routing the ADF Motor cable
ADF EJ Roller
Torsion Spring
Screw it with the
grounding wire.
ADF Motor cable
ADF Motor Unit
Grounding wire
Route it through the rib and groove.