EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW Revision A
TROUBLESHOOTING Error Indications and Fault Occurrence Causes 52
Confidential
• Power on
• Anywhere
When turning on the power, the CR
Motor does not operate at all.
CR Motor
1. Check if the CR Motor Connector Cable is connected to
CN9 on the Main Board.
1. Connect the CR Motor Connector Cable to CN9
on the Main Board.
2. Check if the CR Motor Connector Cable is not damaged. 2. Replace the CR Motor with a new one.
3. Check if the CR Motor operates. 3. Replace the CR Motor with a new one.
When turning on the power, the PF Motor
does not operate at all
PF Motor
1. Check if the PF Motor Connector Cable is connected to
CN10 on the Main Board.
1. Connect the PF Motor Connector Cable to
CN10 on the Main Board.
2. Check if the PF Motor Connector Cable is not damaged. 2. Replace the PF Motor with a new one.
3. Check if the PF Motor operates. 3. Replace the PF Motor with a new one.
Table 3-4. Check point for Fatal error according to each phenomenon
Occurrence
timing
CR position
Detailed phenomenon
Defective
unit/part name
Check point Remedy