2 MENUS
0460 949 274
- 16 -
© ESAB AB 2015
2.1.4 Measurements menu
Main menu
In MEASURE, you can view measured values for various welding parameters while welding
is in progress.
A 450 AMP - Measured welding current
30.0 Volt - Measured arc voltage
50 cm/min - Measured travel speed
300 cm/min - Measured wire speed
30 kJ/cm - Indicates energy per unit length, which is obtained using the values selected
for welding current, arc voltage and travel speed
300 cm/min - Measured cold wire feed speed
The measured values remain in the display even after welding has been completed.
You can move to different menus without losing the measurement values.
The settings knobs can be used to change the welding parameters in the measurement
display.