7.1 Control panel working method
The control panel can be said to comprise two units: working memory and weld data
memory.
Store
Welding data memory
Working Memory
Recall
In the working memory, a complete set of weld data settings is created that can be stored in
the weld data memory.
During welding, it is always the content of the working memory that controls the process. It is
therefore also possible to recall a weld data set from the weld data memory to the working
memory.
Note that the working memory always contains the most recently set weld data settings.
They can be recalled from the weld data memory or individually altered settings. In other
words, the working memory is never empty or “zeroed”.
Main menu → MEMORY → Weld data memory
It is possible to store up to 255 sets of weld data in the control panel. Each set is given a
number from 1 to 255.
You can also delete, copy, change and name data sets and recall a set of weld data to the
working memory.