9 TOOLS
0460 949 274
- 68 -
© ESAB AB 2015
Under ACCOUNT LEVEL choose from:
Administrator
full access (can add new users)
Senior user
can access everything except:
machine configuration
user accounts
network settings
Normal user
can access:
In the Configuration menu:
Maintenance
In the Tools menu:
Unit information
In the Settings menu:
Voltage
Current / wire feed
Travel speed
Welding direction
In the PASSWORD row, key in a password using the keyboard. When the power source is
switched on and the control panel activated, you are asked in the display to enter your
password.
If you choose not to have this function, but instead want the power source and control panel
to be unlocked for all users, select USER ACCOUNTS OFF.