Setup 141
OSC
{OSCRX}
Globally enables receiving OSC.
{OSC RX Port Number}
This setting specifies the UDP port that the console will listen to for OSC receiving strings.
Note: ETC recommends using 8000 and 8001 respectively for port numbers. Remember
that when setting port numbers on your external device that they should be set to the
opposite of what Eos is set. For example, if {OSC TX Port Number} on Eos is set to 8000,
then the RX (incoming) port on your external device needs to be set to 8000, and vice versa.
{OSC Cue Recv String}
Allows the user to specify a different incoming OSC string format for integration with other applic-
ations. Use %1 in the string format as cue number and %2 as the cue list number.
{OSCTX}
Globally enables transmitting OSC.
{OSC TX Port Number}
This sets the UDP destination port to which the console will send OSC strings.
{OSC Cue Send String}
Allows the user to specify a different outgoing OSC string format for integration with other applic-
ations. Use %1 in the string format as cue number and %2 as the cue list number.
{OSC TX IP Address}
This sets the destination IP address or addresses to which the console will send OSC strings.