BlackDiamond 8800 Series Switches Hardware Installation Guide
177
NOTE
Building codes vary worldwide; therefore, Extreme Networks strongly recommends that you consult
an electrical contractor to ensure proper equipment grounding and power distribution for your specific installation
and country.
Selecting Power Supply Cords
Extreme Networks does not provide power input cords in the product box. To purchase a power cord
for your product and for your specific country, contact your local Extreme Networks Channel Account
Manager or Sales Manager, or purchase a cord from your local supplier.
To locate a Sales Manager or Partner in your region visit:
http://www.extremenetworks.com/how-to-buy/how-to-buy.aspx
The following are power cord requirements for use on Extreme switches.
Black Diamond SSI 700/1200 W AC PSU Model 60020:
The power supply cord must be agency-certified for country of use, and rated at 10A by in-country
regulatory authority.
The power supply cord must have an IEC 320 C13, 90-degree angle plug to connect to the IEC320
C14 connector on the power supply.
The power cord must have an appropriately rated and approved wall plug applicable to the country
of installation.
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
2
) minimum; over 6 feet, the
minimum wire size is 16 AWG (1.0 mm
2
).
BlackDiamond 600/900 W AC PSU, Model 41050/PS 2431:
The power supply cord must be agency-certified for the country of use.
The power supply cord must have an IEC 320 C13 plug to connect to the IEC320 C14 connector on
the power supply.
The power supply cord must have an appropriately rated and approved wall plug applicable to the
country of installation.
For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm
2
) minimum; over 6 feet, the
minimum wire size is 16 AWG (1.0 mm
2
).

Table of Contents