EasyManua.ls Logo

Extreme Networks BlackDiamond 8810 - Connector Pinouts

Extreme Networks BlackDiamond 8810
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BlackDiamond 8800 Series Switches Hardware Installation Guide
194
Connector Pinouts
Table 29 describes the pinouts for a DB-9 console plug connector.
Table 28: Specifications for the DC SSI PS Model Number 60021 (1200 W DC PSU)
Compatible with the BlackDiamond 8806 and BlackDiamond 8810 switches
Typical configuration 3 power supplies
Full configuration 6 power supplies
Input Nominal input voltage: –48 V
Voltage input range: –40.5 V to –72 V
Input currents:
–40 V @ 35 A
–48 V @ 30 A
–60 V @ 23 A
Maximum in-rush current: Not more than 80 A for 5 ms
Input circuit protection: 50 A
Wire harness provided by Extreme Networks with each power supply.
Extreme Part Number 4340-00028
Wire type: 8 AWG (10 mm
2
) listed tray cable, copper-stranded rated @ 90 C
minimum
Connector: Molex connector PN 42816-0312
Connector pins: Molex connector pins PN 42815-0032
Output DC output: 48 V , 24 A/12 V , 4 A
DC output power (W): 1200 W
Operating conditions Operating temperature: 0° C to 40° C (32° F to 104 °F)
Operating humidity: 10% to 90% relative humidity, non-condensing
Operating altitude: 0 m to 3,000 m (0 ft to 9,850 ft)
Operational shock*: 30 m/s
2
(3 g), 60 shocks
Operational office vibration*: 5 to 100-5 Hz @ 2/10 G, 0 to peak, 1 oct/min
Operational random vibration*: 3 to 500 Hz @ 1.5 G rms
* Worst case operational condition; not for continuous operation under this
condition
Table 29: Pinouts for the DB-9 Console Connector
Function Pin Number Direction
DCD (data carrier detect) 1 In
RXD (receive data) 2 In
TXD (transmit data) 3 Out
DTR (data terminal ready) 4 Out
GND (ground) 5 -
DSR (data set ready) 6 In
RTS (request to send) 7 Out
CTS (clear to send) 8 In

Table of Contents

Related product manuals