EasyManua.ls Logo

Extreme Networks BlackDiamond 8810 - Verifying the Module Installation

Extreme Networks BlackDiamond 8810
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BlackDiamond 8800 Series Switches Hardware Installation Guide
119
Verifying the Module Installation
After you install a module, verify that it is working correctly by checking the LEDs on the front panel of
the module. Table 22 shows normal LED operation for correctly installed MSMs and I/O modules.
Use the command line interface (CLI)
show slot <slot number> command to display slot-specific
information about the newly installed module.
For more information about LED activity, see the module chapter for each switch series.
Displaying Slot Status Information
Assuming the module has no problems, the command show slot <slot> (where <slot> is the number
of the slot where you installed the module) displays information about the module including: general
information about the module (name, serial number, part number), the state of the module (power
down, operational, mismatch between the slot configuration and the module in the slot), and the
number of ports on the module.
For more information about slot status information, see the ExtremeXOS Concepts Guide and the
ExtremeXOS Command Reference Guide.
Table 22: Module LED Activity for Normal Operation
MSM I/O Module
LED State/Meaning LED State/Meaning
SYS Green blinking STATUS Green blinking
MSTR Green: MSM is primary
Amber: MSM is backup
DIAG Off
ENV Green Port status (per port) Green
Amber blinking
Link/Activity Green: Link is up.
Amber: Packet activity is occurring.

Table of Contents

Related product manuals