·142·
Installation manual
CNC 8055
CNC 8055i
6.
MACHINE PARAMETERS
SOFT: V02.2X
VERIFICATIONS BEFORE STARTUP
In order for the CNC to perform properly, after a setup, check that the following machine parameters
have been set with proper values. This is very important for safety reasons, because if those values
are not the right ones, the machine's performance could be deficient.
General machine parameters
PRODEL (P106)
This parameter the time delay between the instant probing takes place and the CNC is aware of
it. General parameter PRODEL (P106) must be set to 0.
STOPTAP (P116)
This parameter indicates whether general inputs /STOP (M5001), /FEEDHOL (M5002) and
/XFERINH (M5003) are enabled or not while executing function G84. General parameter STOPTAP
(P116) must be set to NO.
INSFEED (P117)
This parameter sets the tool inspection feedrate. General parameter INSFEED (P117) must be set
with a proper value (other than 0).
RAPIDEN (P130)
This parameter indicates whether the "rapid" key affects the execution and the simulation or not.
General parameter RAPIDEN (P130) must be set to 0.
MAXOFFI (P165)
This parameter indicates the maximum amount of wear that may be entered for "I" when modifying
the wear offsets from tool inspection mode. General parameter MAXOFFI (P165) must be set with
a proper value (other than 0).
MAXOFFK (P166)
This parameter indicates the maximum amount of wear that may be entered for "K" when modifying
the wear offsets from tool inspection mode. General parameter MAXOFFK (P166) must be set with
a proper value (other than 0).
FEEDTYPE (P170)
This parameter indicates the behavior of the feedrate when programming F0. General parameter
FEEDTYPE (P170) must be set to 0.
MAXOFFJ (P182)
This parameter indicates the maximum incremental value allowed for Y axis wear compensation.
General parameter MAXOFFJ (P182) must be set with a proper value (other than 0).
Axis parameters
LIMIT+ (P5) and LIMIT- (P6)
These parameters set the travel limits for the axis (positive and negative). Axis parameters LIMIT+
(P5) and LIMIT- (P6) must have the right values
FBACKAL (P11)
This parameter indicates whether the feedback alarm for this axis will be ON or OFF. Axis parameter
FBACKAL (P11) must be set to ON.

Table of Contents