·156·
Installation manual
CNC 8055
CNC 8055i
6.
MACHINE PARAMETERS
SOFT: V02.2X
General machine parameters
INT1SUB (P35) INT2SUB (P36) INT3SUB (P37) INT4SUB (P38)
They indicate the number of the subroutine associated with the corresponding general logic input:
"INT1" (M5024), "INT2" (M5025), "INT3" (M5026)", "INT4" (M5027).
When one of these inputs is activated, the program currently being executed is interrupted and the
CNC jumps to execute the associated subroutine whose number is indicated in the corresponding
parameter.
These interruption subroutines do not change the nesting level of local parameters, thus only global
parameters must be used in them.
Once the CNC completes the execution of the subroutine, it will continue running the original
program.
PRBPULSE (P39)
It indicates whether the probe functions of the CNC act on an up flank (positive pulse) or with the
down flank (negative pulse) of the signal provided by the probe.
At an 8055 CNC, the probe is connected through connector X7 of the AXES module. At an 8055i
CNC, it is possible to have up to two probes connected through connector X3.
PRBXMIN (P40) PRBXMAX (P41) PRBYMIN (P42)
PRBYMAX (P43) PRBZMIN (P44) PRBZMAX (P45)
Indicate the position of the tabletop probe used for tool calibration.
These position values must be absolute and with respect to machine reference zero (home). If a
lathe model CNC, these values must be in radius.
Possible values
Integer numbers between 0 and 9999.
Default value: 0 (no associated subroutine)
Value Meaning
+ sign Positive pulse (24 V or 5 V).
- sign Negative pulse (0 V).
Default value: + sign
Possible values
±99999.9999 mm or ±3937.00787 inches.
Default value: 0
PRBXMIN Probe’s minimum X coordinate.
PRBXMAX Probe’s maximum X coordinate.
PRBYMIN Probe’s minimum Y coordinate.
PRBYMAX Probe’s maximum Y coordinate.
PRBZMIN Probe’s minimum Z coordinate.
PRBZMAX Probe’s maximum Z coordinate.

Table of Contents