Installation manual
CNC 8060
CNC 8065
MACHINE PARAMETERS.
2.
(REF: 1402)
·117·
Machine parameters for the axes and spindles.
PROBERANGE
Maximum braking distance.
Parameter valid for linear and rotary axes.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 99999.9999 mm or degrees / from 0 to 3937.00787 inch.
Default value: 1.0000 mm or degrees / 0.03937 inch.
Associated variable: (V.)[ch].MPA.PROBERANGE.xn
This parameter sets the maximum braking distance for the probe after probing to avoid
breaking it (ceramic, etc). The CNC issues an error messages when this distance is
exceeded.
PROBEFEED
Maximum probing feedrate.
Parameter valid for linear and rotary axes.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 36000000.0000 mm/min or degrees/min / from 0 to 1417322.83465 inch/min.
Default value: 100.0000 mm/min or degrees/min / 3.93701 inch/min.
Associated variable: (V.)[ch].MPA.PROBEFEED.xn
The value of this parameter must be smaller than the feedrate needed to brake within the
distance set by PROBERANGE with the acceleration and jerk values of the axis. Otherwise,
it will show a warning when validating the axis parameters indicating the maximum feedrate
that may be reached.
PROBEDELAY
Delay for the "probe 1" signal.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: Within ±100000.0000 ms.
Default value: 0 (no delay).
Associated variable: (V.)[ch].MPA.PROBEDELAY.xn
See axis machine parameters PROBEDELAY2.
PROBEDELAY2
Delay for the "probe 2" signal.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: Within ±100000.0000 ms.
Default value: 0 (no delay).
Associated variable: (V.)[ch].MPA.PROBEDELAY2.xn
Parameter PROBEDELAY corresponds to the probe set by PRBID1 and PROBEDELAY2
to the probe set by PRBID2.
In some types of probes, there is a short delay of a few milliseconds from the probing instant
to when the CNC actually receives the signals (infrared communication, etc.). In these cases,
it must indicate the time elapsed from when the probing takes place till the CNC receives
the signal.
Probe calibration cycle "#PROBE 2" may be used to set this parameter. After it is executed,
the cycle returns, in arithmetic parameter P298 the best value to be assigned to parameter
PROBEDELAY for the axes and the spindle.