MACHINE PARAMETERS.
(REF: 1402)
General machine parameters.
SHARED PLC MEMORY.
PLCDATASIZE
Size of the PLC's shared data area.
Possible values: From 0 to 500.000 bytes.
Default value: 0.
Associated variable: (V.)MPG.PLCDATASIZE
This parameter may be used to define a memory area to exchange data between a PLC
program written in C language and an external application.
MANAGEMENT OF LOCAL I/O.
NLOCOUT
Number of local digital outputs.
Possible values: From 0 to 8.
Default value: 0.
Associated variable: (V.)MPG.NLOCOUT
The central unit has set of 8 local digital signals, identified as LI/O1 through LI/O8, that may
be configured both as input and output. This parameter indicates how many of these signals,
starting with LI/O1, are configured as digital outputs; the rest of the signals will act as digital
inputs. The following table shows the logict numbers of pins LI/O1-LI/O8 according to
parameter NLOCOUT.
For the PWM and synchronized switching, only local outputs associated with pins LI/O1 and
LI/O2 may be used because they have been set for Laser applications. That requires setting
parameter NLOCOUT = 8.
EXPSCHK
Activate the 24 V monitoring at the local digital outputs.
Possible values: ON / OFF.
Default value: ON.
Associated variable: (V.)MPG.EXPSCHK
When a local digital output is active, the connector must be supplied with 24 V DC. This
parameter enables the detection of these 24 V at the connector.
The 24 V monitoring must be active when a local output has been set; if no local digital output
is active, the 24 V monitoring must be deactivated.
Pin. NLOCOUT
8 7 6 5 4 3 2 1 0
LI/O8 O8O7O6O5O4O3O2O1I16
LI/O7 O7O6O5O4O3O2O1I15I15
LI/O6 O6O5O4O3O2O1I14I14I14
LI/O5 O5O4O3O2O1I13I13I13I13
LI/O4 O4O3O2O1I12I12I12I12I12
LI/O3 O3 O2 O1 I11 I11 I11 I11 I11 I11
LI/O2 O2 O1 I10 I10 I10 I10 I10 I10 I10
LI/O1 O1+ I9 I9 I9 I9 I9 I9 I9 I9