Installation manual
CNC 8060
CNC 8065
MACHINE PARAMETERS.
2.
(REF: 1402)
·69·
General machine parameters.
PRBDI1
Number of the input associated with probe 1.
Possible values: From 1 to 1024 for the remote probe / 1 or 2 for the local probe.
Default value: 0 (no probe is connected).
Associated variable: (V.)MPG.PRBDI1
Parameter included in the PROBEDATA table.
This parameter indicates the number of the input that the probe is connected to. For remote
probes, this parameter indicates the digital input number; for local probes, it indicates the
local probe input number.
The digital input will be a physical input of the module or a logic input of the PLC. The PLC
considers logic inputs the inputs that do not exist physically; for example, if inputs 1 through
256 are numbered at the remote modules, the PLC considers logic inputs the ones from 257
to 1024.
Two remote probes cannot be connected to the same module if they are going to be involved
in simultaneous probing operations; for example, a probe in each channel and both making
a probing movement.
PRBDI2
Number of the input associated with probe 2.
Possible values: From 1 to 1024 for the remote probe / 1 or 2 for the local probe.
Default value: 0 (no probe is connected).
Associated variable: (V.)MPG.PRBDI2
Parameter included in the PROBEDATA table.
This parameter indicates the number of the input that the probe is connected to. For remote
probes, this parameter indicates the digital input number; for local probes, it indicates the
local probe input number.
The digital input will be a physical input of the module or a logic input of the PLC. The PLC
considers logic inputs the inputs that do not exist physically; for example, if inputs 1 through
256 are numbered at the remote modules, the PLC considers logic inputs the ones from 257
to 1024.
Two remote probes cannot be connected to the same module if they are going to be involved
in simultaneous probing operations; for example, a probe in each channel and both making
a probing movement.
PRBPULSE1
Logic level to activate probe 1.
Possible values: Positive / Negative.
Default value: Positive.
Associated variable: (V.)MPG.PRBPULSE1
Parameter included in the PROBEDATA table.
This parameter indicates whether the probe functions are active high (24 V or 5 V) or active
low (0V) of the signal provided by the probe. In any case, the probe signal must be at least
20 ms long for the CNC to consider it valid.
PRBPULSE2
Logic level to activate probe 2.
Possible values: Positive / Negative.
Default value: Positive.
Associated variable: (V.)MPG.PRBPULSE2
Parameter included in the PROBEDATA table.
This parameter indicates whether the probe functions are active high (24 V or 5 V) or active
low (0V) of the signal provided by the probe. In any case, the probe signal must be at least
20 ms long for the CNC to consider it valid.