·68·
Installation manual
CNC 8060
CNC 8065
2.
MACHINE PARAMETERS.
(REF: 1402)
General machine parameters.
PROBE SETTING.
PROBE
There is a probe.
Possible values: Yes / No.
Default value: No.
Associated variable: (V.)MPG.PROBE
This parameter indicates whether there is a probe on the machine or not. The CNC may have
configured two probes, it will usually be a tabletop probe to calibrate tools and a touch probe
to measure the part.
PROBEDATA
Probe parameters.
This parameter shows the table of parameters needed to set up the probe. If the CNC uses
a tabletop probe, besides these parameters it is necessary to define the probe position.
PROBETYPE1
Probe type 1.
Possible values: Remote / Local.
Default value: Remote.
Associated variable: (V.)MPG.PROBETYPE1
Parameter included in the PROBEDATA table.
This parameter indicates the type of probe depending on where it is connected; a remote
probe if it is connected to a digital input at the remote modules or to a local probe if it is
connected to a probe input at the central unit.
PROBETYPE2
Probe type 2.
Possible values: Remote / Local.
Default value: Remote.
Associated variable: (V.)MPG.PROBETYPE2
Parameter included in the PROBEDATA table.
This parameter indicates the type of probe depending on where it is connected; a remote
probe if it is connected to a digital input at the remote modules or to a local probe if it is
connected to a probe input at the central unit.
Tabletop probe. Measuring probe.
PROBEDATA
PROBETYPE1 Probe type 1.
PROBETYPE2 Probe type 2.
PRBDI1 Number of the input associated with probe 1.
PRBDI2 Number of the input associated with probe 2.
PRBPULSE1 Logic level to activate probe 1.
PRBPULSE2 Logic level to activate probe 2.

Table of Contents

Other manuals for Fagor CNC 8060

Related product manuals