What to do if Farr Power Tool torque gauge is indicating incorrectly?
- KKevin ParrishAug 5, 2025
If the torque gauge on your Farr Power Tool is indicating incorrectly, the issue might stem from several causes: * The incorrect gauge may be in use. Ensure the gauge is the proper range and has been properly calibrated for the arm length of the equipment in use. * The gauge may be damaged. Check its operation and calibration on an independent system. * The gauge may have mistakenly been paired with an incorrect load cell. In addition, consider that air trapped in the torque measuring circuit (load cell, hydraulic line, or gauge) could also cause incorrect readings.