C. SAFETY DOOR DOES NOT OPERATE OR IS MALFUNCTIONING
POSSIBLE PROBLEM SOLUTION(S)
1
Safetydoorswitchrequiresadjustment. Adjustswitchaspersection3.F.5
2 Safetydoorswitchhasfailed Testsafetydoorswitchforproperfunctionandreplaceifnecessary
3 Contaminationinhydrauliclines Ensureallthreeflexiblehydrauliclinestosafetydoorswitcharefree-flowing
4
Pilot-to-open valve in safety door valve block is
malfunctioning.
Removeeachvalve.Inspectseatsandsprings.Replacevalve(s)ifdamageisseen
onvalveseats,orifspringappearstobedamagedorbroken.